R803.1 is for lumber sheathing. Nominally, 2-by- The installation of thermoset single-ply roofing shall comply with the provisions of this section. Self-adhering polymer-modified bitumen. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Galvanized fasteners shall be used for steel roofs. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Slate shingles shall be fastened to solidly sheathed roofs. Flashing and counterflashing shall be made with sheet metal. roof sheathing, skylights, change of roof pitch, addition or relocation of mechanical units, or installation of heavier materials than were previously installed. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. DEWALT Building Code Reference: Based on the 2018 International Residential Code | Books & Magazines, Textbooks, Education & Reference, Dictionaries & Reference | eBay! The installation of slate shingles shall comply with the provisions of this section. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Install a two-layer #30 felt underlayment system. Sprayed polyurethane foam roofs shall have a design. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. The installation of modified bitumen roofing shall comply with the provisions of this section. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Above-deck thermal insulation board shall comply with the standards in Table 906.2. Interlayment shall comply with ASTM D226, Type I. A base sheet that complies with the requirements of. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. Roof valley flashing shall be not less than No. The installation of mineral-surfaced roll roofing shall comply with this section. over the entire roof and over the 4-inchwide (102 mm) membrane strips and. 260 0 obj <>stream 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Install flashing at roof penetrations and wall intersections. In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Stainless steel fasteners are acceptable for metal roofs. Install drip edges at eaves and rakes. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Wood shingles shall be laid with a side lap not less than 1, Roof flashing shall be not less than No. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. The installation of asphalt shingles shall comply with the provisions of this section. Slate shingles shall comply with ASTM C 406. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of built-up roofs shall comply with the provisions of this section. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Interlayment shall comply with ASTM D226, Type I. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. satisfy the requirements of 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511, 2012, 2009 and 2006 IBC Section 1510, 2018 and 2021, 2018 and 2015 IRC Section R908 or 2012, 2009 or 2006 IRC Section R907. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, In areas where the average daily temperature in January is 25F (-4C) 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. (R803.1) Hold-Downs and Hardware For the most common roof sheathing in our area, which is 1/2" nominal (7/16" actual) sheathing over trusses or rafters at 24" on center . Modified bitumen roofing shall comply with the standards in Table R905.11.2. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. The installation of wood shingles shall comply with the provisions of this section. Minimum headlap for slate shingles shall be in accordance with Table 905.6.5. A liquid-applied protective coating that complies with Table 905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Sheathing Requirements R905.2.1 Asphalt shingles shall be fastened to solidly sheathed decks. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. For SI: 1 ounce per square foot = 0.305 kg/m. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Valley flashing shall be not less than 15 inches (381 mm) wide. The installation of wood shakes shall comply with the provisions of this section. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Valley flashing shall be not less than 15 inches (381 mm) wide. Table R803.1 is for roof sheathing which requires 5/8 plywood with rafters 24" o.c. Wood shakes shall comply with the requirements of Table R905.8.5. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. 2015 IRC portion of the 2018 CT State Building Code, Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Systems, R909 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances, and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T Recommended Procedure for Worst-Case Testing of Atmospheric Venting Systems Under N1102.4 or N1105 Conditions 5ACH, Appendix U Solar-Ready ProvisionsDetached One- And Two-Family Dwellings, Multiple Single-Family Dwellings (Townhouses), Appendix V Wind Speeds, Seismic Design Categories and Ground Snow Loads, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. (914 mm). Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. On roofs with slope equal to or greater than eight units vertical in 12 units horizontal (67-percent slope), the ice barrier shall also be applied not less than 36 inches (914 mm) measured along the roof slope from the eave edge of the building. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Stainless steel fasteners are acceptable for metal roofs. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Where exterior plaster or adhered masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and Section 703.6.3. It guides the participant through an in-depth review and analysis of the bracing requirements for wood-framed residential structures. 2. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Wolf Hollow Chapter 1, Fayette County Magistrate Court Wv, Airbnb With Hot Tub Greensboro Nc, 2017 2018 Unc Basketball Roster, Mercari Ship On Your Own Option, What Is Chip Kullik Doing Now, Barbara Meshad Dooley Age, The Glamorous Imperial Concubine Happy Or Sad Ending, Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. The installation of liquid-applied roofing shall comply with the provisions of this section. A base sheet that complies with the requirements of Section 1507.11.2 of the. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Asphalt shingle packaging shall bear a, Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not less than four fasteners per strip shingle or two fasteners per individual shingle. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. 2018 IRC. 12 oz/sq ft for preformed metal shingle systems. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Asphalt shingles shall be fastened to solidly sheathed decks. The installation of slate shingles shall comply with the provisions of this section. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Plywood is a wood structural panel covered in R803.2.2 which points you to R503.2.1.1 There is a lot of cross over between chapters 5, 6, and 8, so don't just go with the chapter titles of floor, wall, roof. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing.
Road To The Civil War Worksheet Pdf,
Why Are Consumer Cooperatives Also Called Purchasing Cooperatives?,
Personalized Welcome Signs, Wood,
Eagles Flight Magic Mountain,
Articles OTHER